• On-Line UPS (Single Phase 3~20KVA) (NS)

On-Line UPS (Single Phase 3~20KVA) (NS)

Specially for precision instrument and high end computer
100% made in Taiwan, the On Line UPS system is suitable for load of SMT, OA equipment, automatic testing system, computer and related products. In IGBT/PWM advance and module design, the equipment is highly reliable, excellent quality and exceptional long MTBF.
Model : NS series

Low Frequency Isolated Transformer


RS-232 Communication Interface


Module Packing of IGBT






Adopt low frequency isolated transformer, reliable and safe


RS-232 communication port and SNMP slot allows software controlled automatic shutdown


Main element rectifier and IGBT are packed in module, exceptionally reliable











Dual Display of LED and LCD


Extendable Discharging Time








LED and LCD dual display giving full picture of situations of UPS

Battery capacity can be expanded to extend discharging time and recharging





Model No.

LED Display 

LED+LCD Display

NS-302 

NS-302S

NS-352 

NS-352S

NS-502 

NS-502S

NS-602 

NS-602S

NS-802

NS-802S

NS-103

NS-103S

NS-123 

NS-123S

NS-153 

NS-153S

NS-203

NS-203S

Capacity

3KVA 

2.4KW

3.5KVA 

2.8KW

5KVA 

4KW

6KVA 

4.8KW

8KVA 

6.4KW

10KVA 

8KW

12KVA 

9.6KW

15KVA 

12KW

20KVA 

16KW

Input

Voltage

100V,110V,115V,120V,220V,230V,240V±20%

190V,208V,220V,230V,240V,380V±20%

Frequency

5060Hz±5%

Phase

1Ø2ω+G 1Ø2ω+G or 3Ø3ω+G or 3Ø4ω+G

Output

Voltage

100V,110V,115V,120V or 200V,220V,230V,240V

Frequency Stability

±0.5% (free oscillate)

Voltage Regulation

±1% ±1% (±3% with Isolation Transformer)

Transient Response

<±5% ( 100% load change)

THD

<3% (0~100% linear load)

Waveform

True sine wave

Overload Capability

105% ~ 150% for 30 seconds, >150% for 10 cycle

Short Protection

Can select auto cut-off output and not trip to bypass mode to supply

Crest Factor

31

Transfer Time

Zero-cross transfer or <2 ms. while UPS transfer to bypass

Efficiency

85%

Battery

Battery Type

Lead acid maintenance-free battery

Battery Voltage

192V

Back up Time (PF=0.7)

8mins 6mins 8mins 6mins 5mins 4mins 6mins 9mins 5mins

Recharging Time

5 hours to 90% 8 hours to 90%

Interface


RS232 (LED+LCD display) or dry contact (LED display) or AS-400 (option)

Indicator

LED

Line(green), inverter(green), bypass(orange), battery(green), fault(red), overload(orange), over charge(orange), battery level(5 LED indicators)

LCD

System operating status display, input/output voltage, frequency, output loading %, battery voltage, temperature °C

Audible Alarm

Black Out

Beeping every 4 seconds and auto stopped in about 2 minutes

Battery Low

Rapid beeping every second until battery approaches final discharging

Fault, Over Charging

Beeping continuously

Overload

Beeping 2 seconds on every other second until overload disappeared

Environment

Audible Noise

<50db <60db

Temperature, Humidity

Temperature 0°C~40°C Humidity 0%~90% RH (Non-Condensing)


text3.gifIn low frequency isolated transformer design, safe and reliable
    Inverter adopts low frequency isolation transformer design where inverter and output are totally 
    isolated and can attain excellent protecting effect over the lightning strike, surge, interference from input end

text3.gifInverter adopts full bridge structure and is suitable for all kinds of load
    Full bridge structure is more costly but has wide application and reliability is the highest

text3.gifRectifier and IGBT are module packed
    IGBT is module sealed and is capable of sustaining large current transiently and is fast in heat radiation.
    It is sturdy and durable

text3.gifBattery capacity can be expanded for long time discharge
    In additional standard unit equipped battery, the product can be connected to large capacity battery for 
    long time discharge and can fit with large current charging board to shorten battery recharging time

text3.gifOutput voltage can be adjusted for 10%
    Output voltage of standard unit can be adjusted 10% and custom ordered special voltage can be entertained

text3.gifCan be used as frequency converter with also UPS function
    UPS output can be set to be frequency converter and still maintain the UPS function

text3.gifRS232 contact may be fitted with USB or SNMP card
    If fitted with monitoring software, it can monitor all kinds of situation of UPS

text3.gifLED and LCD dual display, giving full picture of the conditions
    LED can display system status, battery level and failure indicating. LCD can display input voltage, 
    output voltage, frequency, battery voltage, output load level, output battery level, internal temperature 
    that give you full information of UPS status

text3.gifMultiple audio warning functions
    When UPS is with problem, other than light Indicator and LCD display, there are different
    buzzers giving different audio warning

text3.gifLow distortion sine wave output
    With perfect sine wave and harmonic wave distortion at 0 – 100% linear load less than 3%

text3.gifCan be started with battery and auto-restart when mains resumed
    It can be started with UPS internal battery when mains is off.  UPS will be off automatically when 
    battery energy is exhausted.  And when mains recover, UPS will re-start automatically

text3.gifHighly stable output voltage
    Within allowable input voltage range, the serial product maintain less than 1% change in output

text3.gifOver heating protection
    At failure of cooling fan and internal temperatures is too high, the unit will turn off automatically




Office IT Equipment

InternetDataCenter

Data Back Up System




Data Processing Center

Control Room

Automatic Testing Equipment