Additional files

ON_LINE_UPS.pdf
On-Line UPS (low frequency) – NS
Product Introduction

 

Specially for precision instrument and high end computer

100% made in Taiwan, the On Line UPS system is suitable for load of SMT, OA quipment, automatic testing system, computer and related products. In IGBT/PWM advance and module design, the equipment is highly reliable, excellent quality and exceptional long MTBF.

 

Feature:
       

In low frequency isolated transformer design, safe and reliable

LED and LCD dual display, giving full picture of the conditions

 

Inverter adopts low frequency isolation transformer design where inverter and output are totally isolated and can attain excellent protecting effect over the lighting strike, surge, interference from input end

 

LED can display system status, battery level and failure indicating. LCD can display input voltage, output voltage, frequency, battery voltage, output load level, output battery level, internal temperature that give you full information of UPS status
       

Inverter adopts full bridge structure and is suitable for all kinds of load

Multiple audio warning functions

 

Full bridge structure is more costly but has wide application and reliability is the highest, too

 

When UPS is with problem, other than light Indicator and LCD display, there are different buzzers giving different
audio warning
       

Rectifier and IGBT are module packed

Low distortion sine wave output

 

IGBT is module sealed and is capable of sustaining large current transiently and is fast in heat radiation. It is sturdy and durable

 

With perfect sine wave and harmonic wave distortion at 0 – 100% linear load less than 3%
       

Battery capacity can be expanded for long time discharge

Can be started with battery and auto-restart when mains resumed

 

In additional standard unit equipped battery, the product can be connected to large capacity battery for long time discharge and can fit with large current charging board to short battery recharging time

 

When UPS off and power is supplied by internal battery, UPS will be off automatically when battery energy is exhausted. And when mains is resumed, UPS will re-start automatically
       

Output voltage can be adjusted for 10%

Highly stable output voltage

 

Output voltage of standard unit can be adjusted 10% and custom ordered special voltage can be entertained

 

Within allowable input voltage range, the serial product maintain less than 1% change in output
       

Can be used as frequency converter with also UPS function

Over heating protection

  UPS output can be set to be frequency converter and still maintain the UPS function   At failure of cooling fan and internal temperatures is too high, the unit will turn off automatically
       

RS232 contact may be fitted with USB or SNMP card

   
  If fitted with monitoring software, it can monitor all kinds of situation of UPS    
       
Application:

 

Office IT
Equipment

Internet Data
Center
Data Back Up
System

Data Processing
Center

Control Room Automatic Testing
Equipment

 

Function Description:

 

In Micro-
Processor
Control
RS-232
Communication
Interface
Module Packing
of IGBT
Dual Display of
LED and LCD
Extendable
Discharging Time

Adopt low frequency
isolated transformer,
reliable and safe

RS-232 communication
port and SNMP slot
allows software con-
trolled automatic shut-
down

Main element rectifier
and IGBT are packed
in module, exceptionally
reliable

LED and LCD dual
display giving full
picture of situations
of UPS
Battery capacity can
be expanded to extend
discharging time and
recharging

 

Model & Specification:

 

Model No. LED Display
LED+LCD Display
NS-302
NS-302S
NS-352
NS-352S
NS-502
NS-502S
NS-602
NS-602S
NS-802
NS-802S
NS-103
NS-103S
NS-123
NS-123S
NS-153
NS-153S
NS-203
NS-203S
Capacity 3KVA
2.4KW
3.5KVA
2.8KW
5KVA
4KW
6KVA
4.8KW
8KVA
6.4KW
10KVA
8KW
12KVA
9.6KW
15KVA
12KW
20KVA
16KW
Input Voltage 100V,110V,115V,120V,220V,230V,240V±20% 190V,208V,220V,230V,240V,380V±20%
Frequency 50或60Hz±5%
Phase 1ψ 2ω+G 1ψ 2ω+G or 3ψ 3ω+G or 3ψ 4ω+G
Output Voltage 100V,110V,115V,120V or 200V,220V,230V,240V
Frequency Stability ±0.5% (free oscillate)
Voltage Regulation ±1% ±1% (±3% with ISO Transformer)
Transient Response  
THD  
Waveform True sine wave
Overload Capability 105% ~150% for 30 seconds, >150% for 10 cycle
Short Protection Can select auto cut-off output and not trip to bypass mode to supply
Crest Factor 3:1
Transfer Time Zero-cross transfer or
Efficiency ≧85%
Battery Battery Type Lead acid maintenance-free battery
Battery Voltage 192V
Back up Time (PF=0.7) 8 mins 6 mins 8 mins 6 mins 5 mins 4 mins 6 mins 9 mins 5 mins
Recharging Time 5 hours to 90% 8 hours to 90%
Interface   RS232 (LED+LCD display) or dry contact (LED display) or AS-400 (option)
Indicator LED Line(green), inverter(green), bypass(orange), battery(green), fault(red), overload(orange),
over charge(orange), battery level(5 LED indicators)
LCD System operating status display, input/output voltage, frequency, output loading %, battery voltage, temperature ℃
Audible Alarm Black Out Beeping every 4 seconds and auto stopped in about 2 minutes
Battery Low Rapid beeping every second until battery approaches final discharging
Fault, Over Charging Beeping continuously
Overload Beeping 2 seconds on every other second until overload disappeared
Appearance Dimension WxHxD(cm) 24x62x59 27x74x63 29x40x67 35x102x93
Weight(KGS) / WITH ISO. 87 78 118/150 120/154 125/167 156/223 234/303 320/410 336/436
Environment Audible Noise <50db <60db
Temperature, Humidity Temperature: 0℃~40℃   Humidity: 0%~90% RH (Non-Condensing)